{"id":1468,"date":"2025-04-11T17:33:38","date_gmt":"2025-04-11T17:33:38","guid":{"rendered":"https:\/\/www.dioda.ro\/blog\/?p=1468"},"modified":"2025-04-13T06:05:21","modified_gmt":"2025-04-13T06:05:21","slug":"cum-imbunatatesc-eficienta-centralei-termice-in-condensare-scurta-teorie-a-condensarii","status":"publish","type":"post","link":"https:\/\/www.dioda.ro\/blog\/electronica\/cum-imbunatatesc-eficienta-centralei-termice-in-condensare-scurta-teorie-a-condensarii\/","title":{"rendered":"Cum imbun\u0103t\u0103tesc eficien\u021ba centralei termice in condensare ? &#8211; Scurta Teorie a Condensarii"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2025\/04\/image-1.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2025\/04\/image-1.png\" alt=\"\" class=\"wp-image-1475\" srcset=\"https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2025\/04\/image-1.png 1024w, https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2025\/04\/image-1-300x225.png 300w, https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2025\/04\/image-1-768x576.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"how-to-maximise-domestic-condensing-boiler-efficiency\">Cum se maximizeaz\u0103 eficien\u021ba centralei termice in condensare (cele domestice instalare murala)?<\/h2>\n\n\n\n<p>Pentru a maximiza eficien\u021ba&nbsp;<strong>centralei termice \u00een condensare<\/strong>&nbsp;este foarte simplu,&nbsp;<strong>reduce\u021bi temperatura pe tur<\/strong>&nbsp;&#8211; atentie NU temperatura in camera ci temperatura apei care iese din centrala.<\/p>\n\n\n\n<p>Acest lucru nu \u00eenseamn\u0103 c\u0103 elibereaz\u0103 mai pu\u021bin\u0103 energie \u00een general pentru a \u00eenc\u0103lzi proprietatea, ci mai degrab\u0103 poate folosi mai pu\u021bin gaz pentru a elibera aceea\u0219i cantitate de energie. Po\u021bi face acest lucru manual \u00een fiecare zi, \u00een func\u021bie de c\u00e2t de frig este afar\u0103, dar mult mai simplu este s\u0103 folose\u0219ti comenzi de compensare care regleaz\u0103 automat temperatura pe tur pentru tine.<\/p>\n\n\n\n<p>Dar cum aduce asta modificare a temperaturii de tur eficien\u021b\u0103 energetica ?<\/p>\n\n\n\n<p>Principalul motiv pentru care aceasta cre\u0219te eficien\u021ba este energia ad\u0103ugat\u0103 din extrac\u021bia \u201ec\u0103ldurii latente\u201d prin schimbarea de stare a apei.<\/p>\n\n\n\n<p>\u00cen primul r\u00e2nd, ar trebui s\u0103 \u00een\u021belege\u021bi fizica de baz\u0103 a arderii.<\/p>\n\n\n\n<p>CH4 +2O2 = CO2 + 2H2O + C\u0102LDUR\u0102<\/p>\n\n\n\n<p>(Re\u021bine\u021bi c\u0103 este necesar\u0103 sursa de aprindere)<\/p>\n\n\n\n<p>tradus  inseama : 1 Molecula de gazul natural + 2 molecule de oxigen dau 1 dioxid de carbon, dou\u0103 molecule de ap\u0103 (de obicei vapori de ap\u0103) \u0219i c\u0103ldur\u0103.<\/p>\n\n\n\n<p>Deci, \u00een forma sa cea mai pur\u0103, singurele produse secundare ar fi CO2, H20 \u0219i c\u0103ldura. Cu toate acestea, dac\u0103 amestecul de ardere este lipsit de oxigen, risc\u0103m s\u0103 existe un nivel foarte mare de CO (monoxid de carbon) care, dup\u0103 cum va dati seama, este un produs secundar periculos \u0219i nedorit. Pentru a preveni acest lucru, centralele ad\u0103uga, \u00een general,  aer mai mult la amestecul de ardere pentru a men\u021bine partea mai sigur\u0103 a arderii .<\/p>\n\n\n\n<p>Acest lucru are efectul de a dilua POC (produsele arderii), H20 \u0219i CO2, dar face procesul de ardere mai sigur.<\/p>\n\n\n\n<p>Aerul este in general 20,9% O2, 78% azot \u0219i aproximativ 1% alte gaze. Deoarece aerul are doar 15% oxigen, centrala termica va trebui s\u0103 adauge de 4 ori mai mult\u0103 cantitate de alte gaze nenecesare (\u00een principal azot) la ardere, pentru a ob\u021bine o cantitate relativ mic\u0103 de exces de O2. <\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"next-we-should-understand-state-or-phase-change\">\u00cen continuare, ar trebui s\u0103 \u00een\u021belegem schimbarea de stare<\/h2>\n\n\n\n<p>De fiecare dat\u0103 c\u00e2nd H20 \u00ee\u0219i schimb\u0103 faza de la solid la lichid sau gazos, fie absoarbe, fie elibereaz\u0103 ceea ce se nume\u0219te \u201ec\u0103ldur\u0103 latent\u0103\u201d. Valorile variaz\u0103 \u00een func\u021bie de surs\u0103 \u0219i de alte condi\u021bii, cum ar fi presiunea aerului, dar \u00een general, la presiunea atmosferic\u0103, se aplic\u0103 urm\u0103toarele;<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Topire: absoarbe 330.000 J\/kg de c\u0103ldur\u0103 latent\u0103<\/li>\n\n\n\n<li>Evaporare: absoarbe 2.500.000 J\/kg c\u0103ldur\u0103 latent\u0103<\/li>\n\n\n\n<li>Sublimare: absoarbe 2.830.000 J\/kg c\u0103ldur\u0103 latent\u0103<\/li>\n\n\n\n<li>\u00cenghe\u021b: elibereaz\u0103 330.000 J\/kg c\u0103ldur\u0103 latent\u0103<\/li>\n\n\n\n<li>Depunere: elibereaz\u0103 2.830.000 J\/kg c\u0103ldur\u0103 latent\u0103<\/li>\n\n\n\n<li>Condens: elibereaz\u0103 2.500.000 J\/kg el&nbsp;latent<\/li>\n<\/ul>\n\n\n\n<p>Acesta este un maxim teoretic de 690 de wa\u021bi de energie pentru fiecare litru de condens creat.<\/p>\n\n\n\n<p>Acum, dac\u0103 putem crea condens \u00eentr-un schimb\u0103tor de c\u0103ldur\u0103 al cazanului, aceasta este o mul\u021bime de energie poten\u021bial\u0103 care trebuie absorbit\u0103.<\/p>\n\n\n\n<p>De asemenea, merit\u0103 remarcat, pe o baz\u0103 faptic\u0103, c\u0103 aceasta nu este energie \u201eliber\u0103\u201d, aceasta a fost energia care a fost \u00een gaz, dar nu a fost transformat\u0103 \u00een c\u0103ldur\u0103 \u00een timpul procesului de ardere. Era, \u00een esen\u021b\u0103, energia care ie\u0219ea din co\u0219 sub form\u0103 de vapori de ap\u0103. A face acei vapori s\u0103 se condenseze \u00eenainte de a p\u0103r\u0103si cazanul este modul nostru de a recapta acea energie latent\u0103 sub form\u0103 de c\u0103ldur\u0103.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"so-how-do-we-maximise-condensation\">Deci, cum maximiz\u0103m condensarea (si implicit majorarea de economie la gaze) ?<\/h2>\n\n\n\n<p>Condensul are loc atunci c\u00e2nd aerul umed intr\u0103 \u00een contact cu o suprafa\u021b\u0103 mai rece. Temperatura maxim\u0103 a suprafe\u021bei \u00eenainte de condensare este cunoscut\u0103 sub denumirea de punct de rou\u0103 sau punct de satura\u021bie \u0219i va depinde de 2 variabile, presiunea \u0219i umiditatea. Deoarece diferen\u021bele de presiune din interiorul schimb\u0103toarelor noastre de c\u0103ldur\u0103 sunt neglijabile, singurul motiv de \u00eengrijorare este umiditatea.<\/p>\n\n\n\n<p>Deoarece \u0219tim c\u0103 produsul nostru principal al combustiei este CO2 \u0219i H20, iar concentra\u021bia lor este variat\u0103 doar de amestecul de ardere a aerului \u00een exces \u0219i sursa noastr\u0103 de combustibil gazos, m\u0103sur\u00e2nd unul vom avea o indica\u021bie a celuilalt. Adic\u0103, cu c\u00e2t con\u021binutul de CO2 este mai mare, cu at\u00e2t H2O sau umiditatea este mai mare.<\/p>\n\n\n\n<p>Ideal este sa ai o temperatura de retur cat mai scazuta si sub acest punct de roua. Dac\u0103, de asemenea, putem ob\u021bine temperatura pe tur sub acest punct, vom avea suprafa\u021ba maxim\u0103 posibil\u0103 \u00een schimb\u0103torul de c\u0103ldur\u0103 pentru ca condensarea s\u0103 aib\u0103 loc.<\/p>\n\n\n\n<p><strong>Cu toate acestea,<\/strong>&nbsp;exist\u0103 o avertizare! Atunci c\u00e2nd se condenseaz\u0103, umiditatea scade, aceasta, la r\u00e2ndul s\u0103u, scade punctul nostru de rou\u0103 (dorim ca acesta s\u0103 extrag\u0103 mai mult\u0103 c\u0103ldur\u0103 latent\u0103) \u0219i \u00eencetine\u0219te sau opre\u0219te procesul de condensare. Deci, dac\u0103, de exemplu, am avut un schimb\u0103tor de c\u0103ldur\u0103 foarte lung, un punct de rou\u0103 de 55 \u00b0 C \u0219i temperatura schimb\u0103torului de c\u0103ldur\u0103 este egal\u0103 de 54 \u00b0 C peste tot, pute\u021bi presupune c\u0103 \u00een cele din urm\u0103 am putea condensa to\u021bi vaporii \u00een ap\u0103 dac\u0103 schimb\u0103torul de c\u0103ldur\u0103 ar fi suficient de lung. De fapt, de \u00eendat\u0103 ce umiditatea scade u\u0219or, punctul de rou\u0103 scade \u0219i teoretic condensarea se va opri pentru restul schimbului de c\u0103ldur\u0103, deoarece aerul nu mai este \u201esaturat\u201d cu H20. Prin urmare, este sub punctul relativ de satura\u021bie.<\/p>\n\n\n\n<p>Din acest motiv, trebuie s\u0103 urm\u0103rim o temperatur\u0103 de retur c\u00e2t mai sc\u0103zut\u0103 pentru a maximiza efectul de condensare, nu temperatura de tur. <\/p>\n\n\n\n<p>\u0218i, desigur, utilizarea controalelor de compensare va \u00eencerca s\u0103 func\u021bioneze sistemul la o temperatur\u0103 general\u0103 c\u00e2t mai sc\u0103zut\u0103 posibil. Acest lucru ne va asigura c\u0103 ob\u021binem o temperatur\u0103 de retur cu mult sub punctul de rou\u0103, nu \u201edoar sub acesta\u201d, \u0219i vom extrage cantitatea maxim\u0103 de c\u0103ldur\u0103 latent\u0103. Cu c\u00e2t este mai jos de punctul de rou\u0103, cu at\u00e2t se va produce mai mult\u0103 condensare, c\u0103ldura latent\u0103 este absorbit\u0103 \u0219i cu at\u00e2t se economise\u0219te mai mult\u0103 energie.<\/p>\n\n\n\n<p>Urm\u0103toarea diagram\u0103, din nou de la Viessmann, arat\u0103 acest lucru.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2025\/04\/condensing-boiler-lowtemprature.jpg\" alt=\"influen\u021ba diagramei capacit\u0103\u021bii de dimensionare\" class=\"wp-image-2606\"\/><\/figure>\n\n\n\n<p>Pute\u021bi vedea aici ambele sisteme au o temperatur\u0103 medie (medie) de 45\u00b0C, ceea ce \u00eenseamn\u0103 c\u0103 ie\u0219irea lor \u00een camer\u0103 este aceea\u0219i. Dar randamentul inferior \u201e\u00eembun\u0103t\u0103\u0163e\u015fte semnificativ efectul de condensare\u201d.<\/p>\n\n\n\n<p>De fapt, cercetarea comandat\u0103 de Viessmann \u0219i condus\u0103 independent de Universitatea din Salford a constatat recent c\u0103 conectarea unui cazan la sistemele de comanda cu compensare a vremii va reduce consumul de energie cu 15% atunci c\u00e2nd temperatura exterioar\u0103 este de 3\u00b0C, cu 31% c\u00e2nd este 8\u00b0C \u00een aer liber \u0219i cu 45% c\u00e2nd este 12\u00b0C afar\u0103, din cauza temperaturilor de func\u021bionare mai sc\u0103zute ale sistemului. Detalii despre acest studiu sunt mai greu de g\u0103sit, dar o concluzie sensibil\u0103 ar fi c\u0103 radiatoarele mai mari vor avea un efect similar. \u00cen special, economiile generale din acest studiu au fost de numai 15% datorit\u0103 produc\u021biei de ap\u0103 cald\u0103.<\/p>\n\n\n\n<p>Exist\u0103 multe mai multe motive pentru care temperaturile sc\u0103zute adaug\u0103 eficien\u021b\u0103, de exemplu, cu c\u00e2t diferen\u021ba dintre temperatura fl\u0103c\u0103rii \u0219i schimbul de c\u0103ldur\u0103 este mai mare, cu at\u00e2t este mai eficient transferul de c\u0103ldur\u0103, viteze de coroziune mai lente \u0219i componente ale sistemului de \u00eenc\u0103lzire mai bl\u00e2nde\/via\u021b\u0103 prelungit\u0103 a sistemului. Pentru a maximiza absorb\u021bia acestei c\u0103lduri altfel risipite \u0219i a celorlalte beneficii descrise, controlul avansat, compensat de vreme \/ temperatura exterioara, va oferi cele mai sc\u0103zute temperaturi de tur posibile. &nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-can-we-do-to-get-our-flow-temperature-right-down-low\">Ce putem face pentru a sc\u0103dea temperatura pe retur?<\/h2>\n\n\n\n<p>Simplu ! Radiatoare mari!<\/p>\n\n\n\n<p>Caloriferele sunt de obicei dimensionate \u00een func\u021bie de pierderile de c\u0103ldur\u0103 ale camerei tale (c\u00e2t de bine izolate este) \u0219i de dimensiunea camerei. Aceasta ofer\u0103 o cantitate de kW necesar\u0103.<\/p>\n\n\n\n<p>\u00cen mod tradi\u021bional, alege\u021bi apoi un radiator care s\u0103 ofere acea ie\u0219ire cu un flux de 80 de grade \u0219i o temperatur\u0103 de retur de 60 de grade (o temperatur\u0103 medie de 70 \u00b0C). Aceast\u0103 metod\u0103 veche \u00eenvechit\u0103 este \u00eenc\u0103 \u00een uz ast\u0103zi, aceste temperaturi nici m\u0103car nu se vor condensa cu noile modele de centrale.<\/p>\n\n\n\n<p>Dac\u0103 \u00een schimb dublezi dimensiunea caloriferului t\u0103u, acesta va putea oferi aceea\u0219i putere la o temperatur\u0103 medie mult mai sc\u0103zut\u0103, sau chiar mai bine, instala\u021bi cel mai mare calorifer dintre toate adica : \u00eenc\u0103lzirea \u00een pardoseal\u0103.<\/p>\n\n\n\n<p>O alt\u0103 modalitate de a realiza acest lucru este cre\u0219terea izola\u021biei. F\u0103c\u00e2nd acest lucru, v\u0103 supradimensiona\u021bi \u00een mod eficient radiatorul, dar reduce\u021bi \u0219i cantitatea de kilograme de wa\u021bi necesar\u0103, oferind economii mai sensibile.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"so-how-much-efficiency-does-this-add-how-much-gas-can-condensing-save\">Deci, c\u00e2t de mult\u0103 eficien\u021b\u0103 adaug\u0103 asta? C\u00e2t de mult gaz poate economisi condensarea?<\/h2>\n\n\n\n<p>A\u0219a cum pute\u021bi vedea mai jos \u00een acest manual Vaillant, func\u021bionarea cazanului la 50\u00b0C debit \u0219i 30\u00b0C retur a dat o cre\u0219tere cu 8,5% a puterii cazanului fa\u021b\u0103 de func\u021bionarea la 80\/60. Nu doar manualele Valliant ve\u021bi g\u0103si asta, ci \u0219i \u00een toate manualele moderne de cazane \u00een condensa\u021bie.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2025\/04\/consensing-efficiency-1024x452.png\" alt=\"putere g20 sau \u00eenc\u0103rcare date tehnice g20\" class=\"wp-image-1657\"\/><\/figure>\n\n\n\n<p>C\u00e2nd aveti un sistem de compensare in functie de temperatura exterioara, turul se afl\u0103 \u00een mod regulat sub 50 \u00b0C , astfel \u00eenc\u00e2t, \u00een lunile bl\u00e2nde, posibil sa ai o reudcere de p\u00e2n\u0103 la 10%.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2025\/04\/RWT_v_ECB_Graph_Update_2-1-1024x812-1.jpg\" alt=\"temperatura apei pe retur \u00een raport cu randamentul cazanelor \u00een condensare\" class=\"wp-image-2593\"\/><\/figure>\n\n\n\n<p>Deci, dup\u0103 cum pute\u021bi vedea din acest grafic, totul se reduce la ob\u021binerea de temperaturi sc\u0103zute pentru a maximiza condensarea \u0219i eficien\u021ba. \u00cen mod clar, o temperatur\u0103 de retur de 4 \u00b0C este pu\u021bin probabil\u0103, dar o temperatur\u0103 de retur de 15 \u00b0C nu este exclus\u0103 din cauza regresului nocturn compensat de vreme.<\/p>\n\n\n\n<p>Nu uita\u021bi s\u0103 v\u0103 \u00eenscrie\u021bi la newsletter-ul nostru pentru cele mai recente articole!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Cum se maximizeaz\u0103 eficien\u021ba centralei termice in condensare (cele domestice instalare murala)? Pentru a maximiza eficien\u021ba&nbsp;centralei termice \u00een condensare&nbsp;este foarte simplu,&nbsp;reduce\u021bi temperatura pe tur&nbsp;&#8211; atentie NU temperatura in camera ci temperatura apei care iese din centrala. Acest lucru nu \u00eenseamn\u0103 c\u0103 elibereaz\u0103 mai pu\u021bin\u0103 energie \u00een general pentru a \u00eenc\u0103lzi proprietatea, ci mai degrab\u0103 poate &#8230; <a title=\"Cum imbun\u0103t\u0103tesc eficien\u021ba centralei termice in condensare ? &#8211; Scurta Teorie a Condensarii\" class=\"read-more\" href=\"https:\/\/www.dioda.ro\/blog\/electronica\/cum-imbunatatesc-eficienta-centralei-termice-in-condensare-scurta-teorie-a-condensarii\/\" aria-label=\"Read more about Cum imbun\u0103t\u0103tesc eficien\u021ba centralei termice in condensare ? &#8211; Scurta Teorie a Condensarii\">Read more<\/a><\/p>\n","protected":false},"author":1,"featured_media":1476,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[76,10],"tags":[],"class_list":["post-1468","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-centrale-termice","category-electronica"],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2025\/04\/image-2.png","jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/p8WdYv-nG","jetpack_likes_enabled":true,"_links":{"self":[{"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/posts\/1468","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/comments?post=1468"}],"version-history":[{"count":3,"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/posts\/1468\/revisions"}],"predecessor-version":[{"id":1478,"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/posts\/1468\/revisions\/1478"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/media\/1476"}],"wp:attachment":[{"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/media?parent=1468"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/categories?post=1468"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/tags?post=1468"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}