{"id":705,"date":"2023-05-16T04:54:00","date_gmt":"2023-05-16T04:54:00","guid":{"rendered":"https:\/\/www.dioda.ro\/blog\/?p=705"},"modified":"2023-05-31T06:38:41","modified_gmt":"2023-05-31T06:38:41","slug":"controller-mpps-pentru-incalzirea-boilerului-de-la-panouri-fotovoltaice-kit-de-asamblare","status":"publish","type":"post","link":"https:\/\/www.dioda.ro\/blog\/electronica\/scheme-electronice\/controller-mpps-pentru-incalzirea-boilerului-de-la-panouri-fotovoltaice-kit-de-asamblare\/","title":{"rendered":"Controller MPPS pentru incalzirea boilerului de la panouri fotovoltaice &#8211; kit de asamblare"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2023\/05\/image.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"371\" src=\"https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2023\/05\/image-1024x371.png\" alt=\"\" class=\"wp-image-706\" srcset=\"https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2023\/05\/image-1024x371.png 1024w, https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2023\/05\/image-300x109.png 300w, https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2023\/05\/image-768x278.png 768w, https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2023\/05\/image-1536x556.png 1536w, https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2023\/05\/image.png 1759w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p>Descriere de baz\u0103: controler pentru conexiunea optim\u0103 a cazanului AC \u0219i panoului solar, tensiune de intrare 60 p\u00e2n\u0103 la 430 V, curent 16 A. Controlerul are o ie\u0219ire AC \u0219i o ie\u0219ire DC.\u00a0Puterea este indicat\u0103 de LED-uri.\u00a0Set de constructii.<\/p>\n<p>Dori\u021bi s\u0103 economisi\u021bi bani la \u00eenc\u0103lzirea sau la \u00eenc\u0103lzirea apei?\u00a0Cite\u0219te mai departe.\u00a0Sunte\u021bi proprietar de caban\u0103 \u0219i trebuie s\u0103 \u00eenc\u0103lzi\u021bi apa \u00eentr-un cazan vara \u0219i s\u0103 tempera\u021bi cl\u0103direa cu un \u00eenc\u0103lzitor conven\u021bional cu ardere direct\u0103 iarna?\u00a0\u0218i nu pl\u0103ti\u021bi pentru energie?\u00a0Controlerul este \u0219i pentru tine.\u00a0Atentie insa, dispozitivul conectat trebuie sa fie pur rezistiv fara electronica suplimentara (afisaj, termostat electronic, ventilator etc.) si trebuie oprit de un termostat mecanic.<\/p>\n<p>Un kit (plac\u0103 + componente, vezi instruc\u021biunile din sec\u021biunea Desc\u0103rc\u0103ri) pentru cei interesa\u021bi de electronic\u0103.\u00a0Cutie de plastic sau panouri cu orificii pentru o bun\u0103 r\u0103cire (vezi fila Aferent\u0103) pot fi comandate.<\/p>\n<p><strong>Descrierea func\u021bion\u0103rii, versiunea software 9<\/strong><\/p>\n<p>Ce este nou \u00een versiunea 9?\u00a0Timpul de a\u0219teptare pentru conectarea aparatului la ie\u0219irea DC a fost extins la 2 minute, este posibil s\u0103 seta\u021bi tensiunea de ie\u0219ire p\u00e2n\u0103 la 320 V (pentru cei care doresc s\u0103 profite de tensiunea maxim\u0103 de alimentare \u0219i s\u0103 aib\u0103 o bobin\u0103 de \u00eenc\u0103lzire personalizat\u0103 bobinat.), men\u021binerea puterii optime \u00eentre testele panoului a fost \u00eembun\u0103t\u0103\u021bit\u0103 \u0219i este posibil ca set\u0103rile actuale ale controlerului s\u0103 fie indicate de LED-uri.<\/p>\n<p>Controlerul MPPS este un controler de prima genera\u021bie \u0219i optimizeaz\u0103 potrivirea rezisten\u021bei boilerului de \u00eenc\u0103lzire a cazanului \u0219i a panourilor fotovoltaice pentru a maximiza energia recuperat\u0103 din panouri.\u00a0Este conectat intre panoul solar si serpentina de incalzire a cazanului.\u00a0Este proiectat pentru a fi \u00eencorporat \u00een tabloul de distribu\u021bie cu alte dispozitive, cum ar fi deconectatoare, dispozitive de protec\u021bie la supratensiune, contactori etc.<\/p>\n<p>Tensiunea de ie\u0219ire la ie\u0219ire este AC, astfel \u00eenc\u00e2t regulatorul poate fi utilizat \u0219i cu un cazan conven\u021bional cu o bobin\u0103 de \u00eenc\u0103lzire AC.<\/p>\n<p>La ie\u0219ire poate fi conectat un cazan cu o putere de intrare de p\u00e2n\u0103 la 3 kW (p\u00e2n\u0103 la 4 kW cu r\u0103cire activ\u0103).\u00a0Tensiunea de intrare poate fi de la 60 la 430 V \u0219i curentul de intrare p\u00e2n\u0103 la 16 A. Controlerul folose\u0219te o nou\u0103 metod\u0103 de c\u0103utare activ\u0103 a punctului de putere maxim\u0103 (MPPS) atunci c\u00e2nd alimenteaz\u0103 cazanul.\u00a0Aceast\u0103 metod\u0103 elimin\u0103 pierderile de putere \u00een compara\u021bie cu metoda MPPT atunci c\u00e2nd panourile fotovoltaice nu au acelea\u0219i caracteristici, putere nominal\u0103, schimb\u0103ri de temperatur\u0103 sau nu sunt iluminate uniform.\u00a0Cele 6 LED-uri de pe panoul frontal sunt folosite pentru a indica puterea \u0219i curentul de ie\u0219ire.\u00a0Regulatorul are o a doua ie\u0219ire DC la care puterea este redirec\u021bionat\u0103 automat (f\u0103r\u0103 nicio alt\u0103 interven\u021bie) de la panouri \u00een cazul \u00een care centrala este deconectat\u0103 la ie\u0219irea AC.\u00a0Controlerul poate func\u021biona \u00een patru moduri de func\u021bionare, care sunt descrise \u00een textul urm\u0103tor.<\/p>\n<p><strong>Moduri de func\u021bionare ale controlerului:<\/strong><\/p>\n<p>1) ie\u0219ire CA prioritar\u0103, ie\u0219ire CC secundar\u0103: at\u00e2ta timp c\u00e2t o sarcin\u0103 este conectat\u0103 la ie\u0219irea CA (testat\u0103 periodic), ie\u0219irea CC nu se va porni niciodat\u0103.\u00a0Dac\u0103 sarcina de la ie\u0219irea AC este deconectat\u0103, ie\u0219irea DC se porne\u0219te (adic\u0103 exist\u0103 tensiune de panou pe ie\u0219irea DC, dar controlerul nu regleaz\u0103 \u00een niciun fel aceast\u0103 tensiune).\u00a0Dup\u0103 o perioad\u0103 de timp stabilit\u0103, controlerul opre\u0219te ie\u0219irea DC \u0219i \u00eencearc\u0103 s\u0103 testeze dac\u0103 sarcina primar\u0103 de la ie\u0219irea AC a fost reconectat\u0103.\u00a0Dac\u0103 da, las\u0103 ie\u0219irea AC activat\u0103, dac\u0103 nu, porne\u0219te din nou ie\u0219irea DC.<br \/><br \/>2) Ie\u0219ire CC prioritar\u0103, ie\u0219ire CA secundar\u0103: at\u00e2ta timp c\u00e2t o sarcin\u0103 este conectat\u0103 la ie\u0219irea CC (testat\u0103 periodic), ie\u0219irea CA nu se va porni niciodat\u0103.\u00a0Dac\u0103 sarcina de la ie\u0219irea DC este deconectat\u0103, ie\u0219irea AC se porne\u0219te (adic\u0103 ie\u0219irea AC este reglat\u0103 cu tensiune (MPPT). Dup\u0103 o perioad\u0103 de timp stabilit\u0103, controlerul opre\u0219te ie\u0219irea AC \u0219i \u00eencearc\u0103 s\u0103 testeze dac\u0103 sarcina primar\u0103 pe ie\u0219irea DC s-a reconectat.Dac\u0103 da, las\u0103 ie\u0219irea DC activat\u0103, dac\u0103 nu, porne\u0219te din nou ie\u0219irea AC.<br \/>3) Ie\u0219irea AC are \u00eentotdeauna prioritate, ie\u0219irea DC este folosit\u0103 pentru a comuta cele dou\u0103 sarcini folosind un contactor extern: at\u00e2ta timp c\u00e2t sarcina 1 este conectat\u0103 la ie\u0219irea AC (testat\u0103 periodic), ie\u0219irea DC este oprit\u0103.\u00a0Dac\u0103 sarcina 1 este deconectat\u0103 de la ie\u0219irea AC, ie\u0219irea DC este pornit\u0103 (adic\u0103 tensiunea panoului apare pe ie\u0219irea DC).\u00a0Aceast\u0103 tensiune furnizeaz\u0103 o surs\u0103 de alimentare \u00een comuta\u021bie extern\u0103 de 24 VDC* la care este conectat\u0103 bobina contactorului extern*.\u00a0Contactorul comut\u0103 ie\u0219irea AC la sarcina 2, iar controlerul cinci regleaz\u0103 tensiunea de ie\u0219ire (MPPT).\u00a0Dup\u0103 un timp stabilit, controlerul opre\u0219te ie\u0219irea DC, contactorul cade \u0219i sarcina 1 este conectat\u0103 la ie\u0219irea AC.\u00a0Controlerul \u00eencearc\u0103 apoi s\u0103 testeze dac\u0103 sarcina 1 este conectat\u0103.\u00a0Dac\u0103 o face, \u00eencepe s\u0103 regleze tensiunea la sarcina 1, dac\u0103 nu porne\u0219te ie\u0219irea DC,\u00a0aceasta porne\u0219te contactorul, sarcina 2 este conectat\u0103 \u0219i controlerul \u00eencepe s\u0103 regleze tensiunea la sarcina 2. Dac\u0103 nicio sarcin\u0103 nu este conectat\u0103, controlerul folose\u0219te ie\u0219irea DC pentru a comuta contactorul \u00eenainte \u0219i \u00eenapoi p\u00e2n\u0103 c\u00e2nd g\u0103se\u0219te o sarcin\u0103 conectat\u0103.\u00a0\u00cen acest mod, ie\u0219irea DC este utilizat\u0103 numai pentru a comuta sarcinile de la ie\u0219irea AC.<\/p>\n<p>4) Un cazan la ie\u0219irea AC, pe care regulatorul \u00eel conecteaz\u0103 cu un comutator extern PN4316 (folosind ie\u0219irea DC) la tensiunea de re\u021bea de 230 V atunci c\u00e2nd nu exist\u0103 suficient\u0103 energie solar\u0103: scopul este ca apa s\u0103 fie \u00eenc\u0103lzit\u0103 la minimum selectat temperatura seara, chiar \u0219i \u00een zilele \u00een care energia solar\u0103 este redus\u0103.\u00a0\u00cen fiecare test, controlerul evalueaz\u0103 dac\u0103 energia furnizat\u0103 de panouri este suficient\u0103 pentru a \u00eenc\u0103lzi apa din cazan la temperatura selectat\u0103 seara.\u00a0Utilizatorul seteaz\u0103 puterea \u0219i volumul nominal al cazanului \u0219i temperatura minim\u0103 necesar\u0103 a apei.\u00a0Din valorile introduse, regulatorul calculeaz\u0103 cantitatea de energie necesar\u0103.\u00a0Dac\u0103, \u00een timpul testului panoului, controlerul consider\u0103 c\u0103 energia solar\u0103 este insuficient\u0103, porne\u0219te ie\u0219irea DC.<\/p>\n<p>* Alimentarea \u0219i comutatoarele nu sunt incluse \u00een pre\u021bul controlerului, dar le putem furniza.<br \/>Not\u0103: Controlerul folose\u0219te modularea l\u0103\u021bimii impulsului, care poate provoca un zgomot u\u0219or de la bobina de \u00eenc\u0103lzire din cazan, care ar putea perturba lini\u0219tea \u00eenc\u0103perii \u00een care se afl\u0103 centrala.<\/p>\n<p><strong>Date tehnice de baza:<\/strong><\/p>\n<p><strong>Tensiune de alimentare:<\/strong>\u00a060 p\u00e2n\u0103 la 430 V<\/p>\n<p><strong>Curent de intrare:<\/strong>\u00a0maxim 16 A<\/p>\n<p><strong>Tensiunea nominal\u0103 a cazanului:<\/strong>\u00a0reglabil\u0103 de la 10 la 320 V<\/p>\n<p><strong>Tensiunea minim\u0103 a panoului:<\/strong>\u00a0reglabil\u0103 de la 60 la 250 V<\/p>\n<p><strong>Perioada de testare a panoului:<\/strong>\u00a0reglabil\u0103 de la 10 s la 34 de minute<\/p>\n<p><strong>Perioada de testare a termostatului:<\/strong>\u00a0reglabil\u0103 de la 10 s la 34 de minute<\/p>\n<p><strong>Frecven\u021ba de control:<\/strong>\u00a0122 Hz<\/p>\n<p><strong>Ie\u0219iri:<\/strong>\u00a0ie\u0219irea 1 (AC) pentru conectarea unui cazan conven\u021bional AC, ie\u0219irea 2 (DC) pentru conectarea unui alt aparat<\/p>\n<p>Indicator de alimentare: cinci LED-uri albe, interval de la 0 la 100% cu rezolu\u021bie de 5%.<\/p>\n<p>Dimensiuni: 180 x 120 x 45 mm<\/p>\n<p><strong>Alimentare optim\u0103 pentru controler:<\/strong><\/p>\n<p>Tensiunea panoului nu trebuie s\u0103 fie nici prea sc\u0103zut\u0103, nici prea mare.\u00a0Dac\u0103 tensiunea este prea mic\u0103, puterea panourilor nu poate fi \u00eempins\u0103 \u00een sarcin\u0103, o tensiune prea mare va for\u021ba controlerul s\u0103 func\u021bioneze \u00eentr-o pozi\u021bie dezavantajoas\u0103 sau chiar l-ar putea deteriora.\u00a0Tensiunea optim\u0103 de alimentare ar trebui s\u0103 fie \u00eentre 100 \u0219i 115% din tensiunea nominal\u0103 de sarcin\u0103 (aceasta este de obicei 230 V).\u00a0Tensiunea de alimentare este calculat\u0103 ca produsul dintre num\u0103rul de panouri \u00een serie \u0219i tensiunea acestora la punctul de func\u021bionare (valoarea mai mic\u0103 a tensiunii din documenta\u021bia panoului).\u00a0Puterea de v\u00e2rf optim\u0103 a panourilor (vezi din nou documenta\u021bia panoului) ar trebui s\u0103 fie \u00eentre 100 \u0219i 125 % din puterea de sarcin\u0103.\u00a0Respectarea acestor condi\u021bii va oferi cel mai favorabil raport cost\/energie.\u00a0Dac\u0103 utiliza\u021bi un aparat pentru tensiuni mai mari de 230 V,\u00a0tensiunea de alimentare poate fi mai mare (se recomand\u0103 totu\u0219i ca tensiunea de alimentare s\u0103 fie de 100 p\u00e2n\u0103 la 115 % din tensiunea nominal\u0103 de sarcin\u0103).\u00a0Dar chiar \u0219i \u00een acest caz, num\u0103rul maxim de panouri \u00een serie poate fi doar astfel \u00eenc\u00e2t tensiunea lor f\u0103r\u0103 sarcin\u0103 s\u0103 nu dep\u0103\u0219easc\u0103 niciodat\u0103 430 V. Controlul este u\u0219or.\u00a0\u00cen documenta\u021bia panoului pute\u021bi g\u0103si tensiunea \u00een gol (aceasta este cea mai mare valoare dat\u0103), \u00eenmul\u021bi\u021bi-o cu 1,15 pentru a calcula tensiunea panourilor la o temperatur\u0103 exterioar\u0103 de -25 de grade.\u00a0C. \u00cenmul\u021bi\u021bi tensiunea rezultat\u0103 cu num\u0103rul de panouri din serie.\u00a0Tensiunea calculat\u0103 trebuie s\u0103 fie \u00eentotdeauna mai mic\u0103 de 430 V!\u00a0Dac\u0103 nu este, trebuie redus num\u0103rul de panouri!\u00a0Controlul este u\u0219or.\u00a0\u00cen documenta\u021bia panoului pute\u021bi g\u0103si tensiunea \u00een gol (aceasta este cea mai mare valoare dat\u0103), \u00eenmul\u021bi\u021bi-o cu 1,15 pentru a calcula tensiunea panourilor la o temperatur\u0103 exterioar\u0103 de -25 de grade.\u00a0C. \u00cenmul\u021bi\u021bi tensiunea rezultat\u0103 cu num\u0103rul de panouri din serie.\u00a0Tensiunea calculat\u0103 trebuie s\u0103 fie \u00eentotdeauna mai mic\u0103 de 430 V!\u00a0Dac\u0103 nu este, trebuie redus num\u0103rul de panouri!\u00a0Controlul este u\u0219or.\u00a0\u00cen documenta\u021bia panoului pute\u021bi g\u0103si tensiunea \u00een gol (aceasta este cea mai mare valoare dat\u0103), \u00eenmul\u021bi\u021bi-o cu 1,15 pentru a calcula tensiunea panourilor la o temperatur\u0103 exterioar\u0103 de -25 de grade.\u00a0C. \u00cenmul\u021bi\u021bi tensiunea rezultat\u0103 cu num\u0103rul de panouri din serie.\u00a0Tensiunea calculat\u0103 trebuie s\u0103 fie \u00eentotdeauna mai mic\u0103 de 430 V!\u00a0Dac\u0103 nu este, trebuie redus num\u0103rul de panouri!<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"https:\/\/www.dioda.ro\/invertoare-panouri-fotovoltaice\/44648-controler-mpps-pentru-alimentarea-cazanului-de-la-panouri-fotovoltaice-kit.html\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2023\/05\/controler-mpps-pentru-alimentarea-cazanului-de-la-panouri-fotovoltaice-kit.jpg\" alt=\"\" class=\"wp-image-710\" width=\"819\" height=\"935\" srcset=\"https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2023\/05\/controler-mpps-pentru-alimentarea-cazanului-de-la-panouri-fotovoltaice-kit.jpg 368w, https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2023\/05\/controler-mpps-pentru-alimentarea-cazanului-de-la-panouri-fotovoltaice-kit-263x300.jpg 263w\" sizes=\"auto, (max-width: 819px) 100vw, 819px\" \/><\/a><\/figure>\n\n\n\n<p><a href=\"https:\/\/www.dioda.ro\/invertoare-panouri-fotovoltaice\/44648-controler-mpps-pentru-alimentarea-cazanului-de-la-panouri-fotovoltaice-kit.html\">https:\/\/www.dioda.ro\/invertoare-panouri-fotovoltaice\/44648-controler-mpps-pentru-alimentarea-cazanului-de-la-panouri-fotovoltaice-kit.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Descriere de baz\u0103: controler pentru conexiunea optim\u0103 a cazanului AC \u0219i panoului solar, tensiune de intrare 60 p\u00e2n\u0103 la 430 V, curent 16 A. Controlerul are o ie\u0219ire AC \u0219i o ie\u0219ire DC.\u00a0Puterea este indicat\u0103 de LED-uri.\u00a0Set de constructii. Dori\u021bi s\u0103 economisi\u021bi bani la \u00eenc\u0103lzirea sau la \u00eenc\u0103lzirea apei?\u00a0Cite\u0219te mai departe.\u00a0Sunte\u021bi proprietar de caban\u0103 \u0219i &#8230; <a title=\"Controller MPPS pentru incalzirea boilerului de la panouri fotovoltaice &#8211; kit de asamblare\" class=\"read-more\" href=\"https:\/\/www.dioda.ro\/blog\/electronica\/scheme-electronice\/controller-mpps-pentru-incalzirea-boilerului-de-la-panouri-fotovoltaice-kit-de-asamblare\/\" aria-label=\"Read more about Controller MPPS pentru incalzirea boilerului de la panouri fotovoltaice &#8211; kit de asamblare\">Read more<\/a><\/p>\n","protected":false},"author":1,"featured_media":707,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[33],"tags":[],"class_list":["post-705","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-scheme-electronice"],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/www.dioda.ro\/blog\/wp-content\/uploads\/2023\/05\/mpps-regulator-pro-napajeni-boileru-z-fotovoltaick.jpg.big_.jpg","jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/p8WdYv-bn","jetpack_likes_enabled":true,"_links":{"self":[{"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/posts\/705","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/comments?post=705"}],"version-history":[{"count":0,"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/posts\/705\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/media\/707"}],"wp:attachment":[{"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/media?parent=705"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/categories?post=705"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dioda.ro\/blog\/wp-json\/wp\/v2\/tags?post=705"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}